(point name type value [conf security locked seconds nanoseconds [quality]])
The name of the point.
The type of the point.
The value of the point.
The confidence level of the point.
The security level of the point.
The locked status of the point.
The current time in seconds.
The number of nanoseconds past seconds .
The quality of the point.
This command is the string that the DataHub sends to all clients when a point value changes (i.e. a point exception occurs). The DataHub also listens for a point command because this is the mechanism that it uses to get updates from another DataHub that it is tunnelling. This is not a command that a user would normally emit. Point changes should be sent to the DataHub using the write or cwrite commands.